Hardware version

CANBench TrueZ v1.1 — Fabricated prototype, sole built unit. V1.1 is electrically identical to the V1.2 schematic refresh but predates the InvenTree symbol-library migration; the schematic component metadata reflects legacy SCADYS naming. Testing and bench validation reference this V1.1 hardware.

Other versions: v1.2 — schematic refresh (next version)

Operator manual for the CANBench TrueZ — the common-mode / differential-mode separation stage that sits between a CANBench Duo LISN and a spectrum analyser. Pick the page you need.

PageWhat's on it
Quick StartCable the TrueZ between the Duo's two LISN outputs and the analyser, then sweep
Spectrum-Analyser SetupAnalyser configuration; the mandatory 50 Ω-input requirement
Measurement ProcedureNoise-floor check, baseline, CM sweep, DM sweep, low-end correction
Common PitfallsMistakes that produce wrong CM/DM readings and how to avoid them
Interpreting ResultsReading the CM vs DM split and choosing the right mitigation